MC68HC908AZ60 Datasheet, PDF (373/480 Pages) Motorola, Inc – HCMOS Microcontroller Unit | |||
|
◁ |
MSCAN Controller (MSCAN08)
Programmerâs Model of Control Registers
MSCAN08
Receiver Interrupt
Enable Register
Address: $0505
Bit 7
6
5
4
3
2
1
Bit 0
Read:
WUPIE RWRNIE TWRNIE RERRIE TERRIE BOFFIE
Write:
OVRIE
RXFIE
Reset: 0
0
0
0
0
0
0
0
Figure 20. Receiver Interrupt Enable Register (CRIER)
WUPIE â Wakeup Interrupt Enable
1 = A wakeup event will result in a wakeup interrupt.
0 = No interrupt will be generated from this event.
RWRNIE â Receiver Warning Interrupt Enable
1 = A receiver warning status event will result in an error interrupt.
0 = No interrupt is generated from this event.
TWRNIE â Transmitter Warning Interrupt Enable
1 = A transmitter warning status event will result in an error
interrupt.
0 = No interrupt is generated from this event.
RERRIE â Receiver Error Passive Interrupt Enable
1 = A receiver error passive status event will result in an error
interrupt.
0 = No interrupt is generated from this event.
TERRIE â Transmitter Error Passive Interrupt Enable
1 = A transmitter error passive status event will result in an error
interrupt.
0 = No interrupt is generated from this event.
BOFFIE â Bus-Off Interrupt Enable
1 = A bus-off event will result in an error interrupt.
0 = No interrupt is generated from this event.
OVRIE â Overrun Interrupt Enable
1 = An overrun event will result in an error interrupt.
0 = No interrupt is generated from this event.
41-mscan
MOTOROLA
MSCAN Controller (MSCAN08)
MC68HC908AZ60 â Rev 2.0
371
|
▷ |