Electrical SpecificationOperating Conditions
Table 3-5 Operating Conditions (cont’d)
Parameter
Symbol
Values
Unit Note / Test Condition
Min.
Typ.
Max.
Digital supply voltage for EBU VEBU SR 2.97
3.3
3.63
V
3.3V pad parameters
are valid; only required
if externally supplied
Digital external supply voltage VEVRSB SR 2.97
-
for EVR and during Standby
mode
5.5
V
Digital supply voltage for EBU VFLEXE SR 2.97
3.3
4.5
V
3.3V pad parameters
Flex port
are valid
4.5
5.0
5.5
V
5V pad parameters are
valid
1) VDD = 1.33V +- 7.5% (with increased nominal VDD) voltage by +2.5%.
2) No external inductive load permissible if EVR is used. All VDD pins shall be connected together externally on the PCB.
3) Voltage overshoot to 1.69V is permissible, provided the duration is less than 2h cumulated. Reduced ADC accuracy and
leakage is increased.
4) Voltage overshoot to 6.5V is permissible, provided the duration is less than 2h cumulated. Reduced ADC accuracy and
leakage is increased.
5) All VEXT pins shall be connected together externally on the PCB.
6) All VDDP3 pins shall be connected together externally on the PCB.
7) Voltage overshoot to 4.29V is permissible, provided the duration is less than 2h cumulated. Reduced ADC accuracy and
leakage is increased.
8) This parameter is valid under the assumption the PORST signal is constantly at low level during the power-up/power-down
of VDDP3.