Register Description
AcceptedCells/
Packets
(31:16)
Count of Accepted Cells or AAL5 Units within this traffic class,
depending on flag SCNT in TCT3.
If SCNT = 0:
This counter is incremented when a user data cell with AAL_
indication=1 is accepted (Packet end indication in AAL5: PTI= xx1).
If SCNT = 1 all accepted cells are counted
Do not Write in normal operation.
Must be reset after Read access.
•
Register WAR.Word64Sel(1:0) =’11’:
Bit
15
14
13
12
11
10
9
8
LostCellsTotal(31:24)
Bit
7
6
5
4
3
2
1
0
LostCellsTotal(23:16)
LostCellsTotal
(31:16)
Count of all lost cells for this traffic class.