English
Language : 

PXF4336 Datasheet, PDF (256/425 Pages) Infineon Technologies AG – ABM Premium ATM Buf fer Manager
Register WAR.Word64Sel(1:0) =’01’:
ABM-P
PXF 4336 V1.1
Register Description
Bit
15
14
13
12
11
10
9
8
TrafClassMax(7:0)
Bit
7
6
5
4
3
2
1
0
SBMax(7:0)
TrafClassMax
(7:0)
Maximum Traffic Class Fill Threshold (determines the maximum
number of cells in all queues associated with this traffic class). The
threshold is defined with a granularity of 1024:
Threshold = TrafClassMax(7:0) * 1024 Cells
SBMax(7:0)
Combined Threshold of the Maximum Number of Buffered
Cells in the Scheduler Block; that is, all cells which are in the traffic
classes (= cells in the corresponding queues) of the Scheduler
Block for the following cases:
a) If EPDen=0 and ABRen=0
Þ Maximum Scheduler Block fill threshold for CLP=’0/1’ cells
b) If EPDen=1 and ABRen=0
Þ EPD Scheduler Block threshold
c) If ABRen=1
Þ CI Scheduler Block threshold for ABR connections
(Set CI-Bit (Congestion Indication) in the RM cells)
The threshold is defined with a granularity of 1024:
Threshold = SBMax(7:0) * 1024 Cells
Register WAR.Word64Sel(1:0) =’10’:
Bit
15
14
13
12
11
10
9
8
AcceptedCells/Packets(31:24)
Bit
7
6
5
4
3
2
1
0
AcceptedCells/Packets(23:16)
Data Sheet
256
2001-12-17