English
Language : 

PXF4336 Datasheet, PDF (183/425 Pages) Infineon Technologies AG – ABM Premium ATM Buf fer Manager
ABM-P
PXF 4336 V1.1
Register Description
Internal table entries contain bit fields for internal device operation only. Table 7-1
identifies the color conventions used for the various types of fields described in this
register chapter:
Table 7-1 Color Convention for Internal Table Field Illustration
Color
Meaning
Grey shaded fields are ’unused’. Reading these fields will return ’0’.
Green shaded fields require attention by CPU. They can be written or read
by CPU; usage depends on the respective field description. Typically
green fields must be written for initialization and configuration or read for
status query.
Blue shaded fields require/allow READ attention by CPU.
Typically blue fields provide counter or status information.
The CPU MUST NOT write to blue fields.
Red shaded fields are for device internal use only and require NO attention
by CPU.
The CPU MUST NOT write to red fields.
•Table 7-2 ABM-P Registers Overview
Addr Register
(hex)
Description
Cell Flow Test Registers
01/11 UCFTST/
DCFTST
Upstream/Downstream Cell Flow Test
Registers
SDRAM Configuration Registers
02/12 URCFG/
DRCFG
Upstream/Downstream SDRAM
Configuration Registers
03/13 -
Reserved Register
04/14 -
Reserved Register
Cell Insertion/Extraction and AAL5 Control Registers
05/15 UA5TXHD0/
DA5TXHD0
Upstream/Downstream AAL5 Transmit
Header 0 Registers
06/16 UA5TXHD1/
DA5TXHD1
Upstream/Downstream AAL5Transmit
Header 1 Registers
07/17 UA5TXDAT0/ Upstream/Downstream AAL5Transmit
DA5TXDAT0 Data 0 Registers
Reset µP
value
See
page
(hex)
0000 R/W 194
0033 R/W 195
0000 R -
0000 R -
0000 R/W 196
0000 R/W 198
0000 R/W 200
Data Sheet
183
2001-12-17