English
Language : 

PXB4219 Datasheet, PDF (248/290 Pages) Infineon Technologies AG – IWE8 Interworking Element for 8 E1/T1 Lines
PXB4219 / PXB4220 / PXB4221
Electrical Characteristics
Table 34 Clock and Reset Interface AC Timing Characteristics (cont’d)
No. Parameter
Limit Values
Unit
Min
Typ
Max
GIM T1:
18,53 25
38,88 MHz
others:
24,58 25
38,88 MHz
2
TCLK52: Period CLK522)
2A
FCLK52: Frequency CLK52 2)
-50 ppm 19.29
-50 ppm 51.84
+50 ppm ns
+50 ppm MHz
3
Pulse width RESET low
3xTCLOCK
1) The frequency should be equal or higher than RXCLK and TXCLK of the UTOPIA interface
2) Only required if the Internal Clock Recovery Circuit is used for SRTS
9.6.2 Framer Interface
9.6.2.1 Framer Interface in FAM
Framer Receive Interface
1
RFCLK
2
FRCLK
3
3
FRFRS
4
5
FRDAT
6
7
FRMFB
Figure 57 Framer Receive Interface Timing in FAM
Data Sheet
248
2002-05-06