7.31
Command Register (cmd)
Read/write Address 00025H
Reset value 0000H
PXB4219 / PXB4220 / PXB4221
Register Description
15
7
Not used
Not used
insert_
cell
pt2_
comp
pt1_
comp
vci2_
comp
8
0
vci1_
comp
vci1_comp
vci2_comp
pt1_comp
pt2_comp
insert_cell
VCI comparison corresponding to register cfvp1 and cfvm1.
0 = Disabled
1 = Enabled
VCI comparison corresponding to register cfvp2 and cfvm2.
0 = Disabled
1 = Enabled
PT comparison corresponding to fields pt_pattern1 and pt_mask1 in
register cfpt.
0 = Disabled
1 = Enabled
PT comparison corresponding to fields pt_pattern2 and pt_mask2 in
register cfpt.
0 = Disabled
1 = Enabled
Cell insertion via microprocessor.
A cell will be inserted in the data stream as soon as possible; when
finished this bit will be reset.
0 = Disabled
1 = Enabled
Data Sheet
186