English
Language : 

CDCE62005 Datasheet, PDF (34/76 Pages) Texas Instruments – Five/Ten Output Clock Generator/Jitter Cleaner With Integrated Dual VCOs
CDCE62005
SCAS862 – NOVEMBER 2008........................................................................................................................................................................................... www.ti.com
Device Registers: Register 7
SPI RAM BIT NAME
BIT BIT
0
A0
1
A1
2
A2
3
A3
4
0 LFRCSEL0
5
1 LFRCSEL1
6
2 LFRCSEL2
7
3 LFRCSEL3
8
4 LFRCSEL4
9
5 LFRCSEL5
10 6 LFRCSEL6
11 7 LFRCSEL7
12 8 LFRCSEL8
13 9 LFRCSEL9
14 10 LFRCSEL10
15 11 LFRCSEL11
16 12 LFRCSEL12
17 13 LFRCSEL13
18 14 LFRCSEL14
19 15 LFRCSEL15
20 16 LFRCSEL16
21 17 LFRCSEL17
22 18 LFRCSEL18
23 19 LFRCSEL19
24 20 LFRCSEL20
25 21 RESERVED
26 22 TESTMUX1
27 23 SEL_DEL2
28 24 TEXTMUX2
29 25 SEL_DEL1
30 26 EPLOCK
31 27 RESERVED
Table 12. CDCE62005 Register 7 Bit Definitions
RELATED DESCRIPTION/FUNCTION
BLOCK
Address 0
Address 1
Address 2
Address 3
VCO Core Loop Filter Control Setting
VCO Core Loop Filter Control Setting
VCO Core Loop Filter Control Setting
VCO Core Loop Filter Control Setting
VCO Core Loop Filter Control Setting
VCO Core Loop Filter Control Setting
VCO Core Loop Filter Control Setting
VCO Core Loop Filter Control Setting
VCO Core Loop Filter Control Setting
VCO Core Loop Filter Control Setting
VCO Core Loop Filter Control Setting
VCO Core Loop Filter Control Setting
VCO Core Loop Filter Control Setting
VCO Core Loop Filter Control Setting
VCO Core Loop Filter Control Setting
VCO Core Loop Filter Control Setting
VCO Core Loop Filter Control Setting
VCO Core Loop Filter Control Setting
VCO Core Loop Filter Control Setting
VCO Core Loop Filter Control Setting
VCO Core Loop Filter Control Setting
—
Must be set to "0"
Diagnostics Set to “1”
Smart Mux
If set to “0” it enables short delay for fast operation
If Set to “1” Long Delay recommended for Input References below 150MHz.
Diagnostics Set to “1”
Smart Mux
If set to “0” it enables short delay for fast operation
If Set to “1” Long Delay recommended for Input References below 150MHz.
Status
Read Only
If EPLOCK reads “0” EEPROM is unlocked. If EPLOCK reads “1”, then the
EEPROM is locked (see Table 4 for how to lock the EEPROM – this can only
be executed once after which the EEPROM is locked permanently).
Status Read Only Always reads “1”
1
1
1
0
EEPROM
EEPROM
EEPROM
EEPROM
EEPROM
EEPROM
EEPROM
EEPROM
EEPROM
EEPROM
EEPROM
EEPROM
EEPROM
EEPROM
EEPROM
EEPROM
EEPROM
EEPROM
EEPROM
EEPROM
EEPROM
EEPROM
EEPROM
EEPROM
EEPROM
EEPROM
EEPROM
EEPROM
34
Submit Documentation Feedback
Product Folder Link(s) :CDCE62005
Copyright © 2008, Texas Instruments Incorporated