English
Language : 

PIC16F193X Datasheet, PDF (318/418 Pages) Microchip Technology – 28/40/44-Pin Flash-Based, 8-Bit CMOS Microcontrollers with LCD Driver and nanoWatt Technology
PIC16F193X/LF193X
22.6.13.1 Bus Collision During a Start
Condition
During a Start condition, a bus collision occurs if:
a) SDA or SCL are sampled low at the beginning of
the Start condition (Figure 22-29).
b) SCL is sampled low before SDA is asserted low
(Figure 22-30).
During a Start condition, both the SDA and the SCL
pins are monitored.
If the SDA pin is already low, or the SCL pin is already
low, then all of the following occur:
• the Start condition is aborted,
• the BCLIF flag is set and
• the MSSP module is reset to its Idle state
(Figure 22-29).
The Start condition begins with the SDA and SCL pins
deasserted. When the SDA pin is sampled high, the
Baud Rate Generator is loaded and counts down. If the
SCL pin is sampled low while SDA is high, a bus colli-
sion occurs because it is assumed that another master
is attempting to drive a data ‘1’ during the Start
condition.
If the SDA pin is sampled low during this count, the
BRG is reset and the SDA line is asserted early
(Figure 22-31). If, however, a ‘1’ is sampled on the SDA
pin, the SDA pin is asserted low at the end of the BRG
count. The Baud Rate Generator is then reloaded and
counts down to zero; if the SCL pin is sampled as ‘0’
during this time, a bus collision does not occur. At the
end of the BRG count, the SCL pin is asserted low.
Note:
The reason that bus collision is not a factor
during a Start condition is that no two bus
masters can assert a Start condition at the
exact same time. Therefore, one master
will always assert SDA before the other.
This condition does not cause a bus colli-
sion because the two masters must be
allowed to arbitrate the first address fol-
lowing the Start condition. If the address is
the same, arbitration must be allowed to
continue into the data portion, Repeated
Start or Stop conditions.
FIGURE 22-30:
SDA
BUS COLLISION DURING START CONDITION (SDA ONLY)
SDA goes low before the SEN bit is set.
Set BCLIF,
S bit and SSPIF set because
SDA = 0, SCL = 1.
SCL
SEN
BCLIF
S
Set SEN, enable Start
condition if SDA = 1, SCL = 1
SDA sampled low before
Start condition. Set BCLIF.
S bit and SSPIF set because
SDA = 0, SCL = 1.
SEN cleared automatically because of bus collision.
SSP module reset into Idle state.
SSPIF and BCLIF are
cleared by software
SSPIF
SSPIF and BCLIF are
cleared by software
DS41364A-page 316
Preliminary