S912XEP100J5MAG Datasheet, PDF (1117/1324 Pages) Freescale Semiconductor, Inc – Features of the MC9S12XE-Family are listed here. Please see Table D-2.for memory options and Table D-2. for the peripheral features that are available on the different family members. | |||
|
◁ |
Register
FSTAT
FERSTAT
Chapter 28 768 KByte Flash Module (S12XFTM768K4V2)
Table 28-40. Read Once Command Error Handling
Error Bit
ACCERR
FPVIOL
MGSTAT1
MGSTAT0
EPVIOLIF
Error Condition
Set if CCOBIX[2:0] != 001 at command launch
Set if a Load Data Field command sequence is currently active
Set if command not available in current mode (see Table 28-30)
Set if an invalid phrase index is supplied
None
Set if any errors have been encountered during the read
Set if any non-correctable errors have been encountered during the read
None
28.4.2.5 Load Data Field Command
The Load Data Field command is executed to provide FCCOB parameters for multiple P-Flash blocks for
a future simultaneous program operation in the P-Flash memory space.
Table 28-41. Load Data Field Command FCCOB Requirements
CCOBIX[2:0]
FCCOB Parameters
000
0x05
Global address [22:16] to
identify P-Flash block
001
Global address [15:0] of phrase location to be programmed(1)
010
Word 0
011
Word 1
100
Word 2
101
1. Global address [2:0] must be 000
Word 3
Upon clearing CCIF to launch the Load Data Field command, the FCCOB registers will be transferred to
the Memory Controller and be programmed in the block speciï¬ed at the global address given with a future
Program P-Flash command launched on a P-Flash block. The CCIF ï¬ag will set after the Load Data Field
operation has completed. Note that once a Load Data Field command sequence has been initiated, the Load
Data Field command sequence will be cancelled if any command other than Load Data Field or the future
Program P-Flash is launched. Similarly, if an error occurs after launching a Load Data Field or Program
P-Flash command, the associated Load Data Field command sequence will be cancelled.
Freescale Semiconductor
MC9S12XE-Family Reference Manual Rev. 1.25