DCM Timing Parameters
All devices are 100% functionally tested. Because of the dif-
ficulty in directly measuring many internal timing parame-
ters, those parameters are derived from benchmark timing
patterns. The following guidelines reflect worst-case values
Operating Frequency Ranges
across the recommended operating conditions. All output
jitter and phase specifications are determined through sta-
tistical measurement at the package pins.
Table 61: Operating Frequency Ranges
Description
Symbol
Constraints Value
Output Clocks (Low Frequency Mode)
CLK0, CLK90, CLK180, CLK270
CLKOUT_FREQ_1X_LF_Min
24.00
CLKOUT_FREQ_1X_LF_Max
180.00
CLK2X, CLK2X180
CLKOUT_FREQ_2X_LF_Min
48.00
CLKOUT_FREQ_2X_LF_Max
360.00
CLKDV
CLKOUT_FREQ_DV_LF_Min
1.50
CLKOUT_FREQ_DV_LF_Max
120.00
CLKFX, CLKFX180
CLKOUT_FREQ_FX_LF_Min
24.00
CLKOUT_FREQ_FX_LF_Max
210.00
Input Clocks (Low Frequency Mode)
CLKIN (using DLL outputs) (1), (3)
CLKIN_FREQ_DLL_LF_Min
24.00
CLKIN (using CLKFX outputs) (2), (3)
CLKIN_FREQ_DLL_LF_Max
CLKIN_FREQ_FX_LF_Min
180.00
1.00
CLKIN_FREQ_FX_LF_Max
210.00
PSCLK
PSCLK_FREQ_LF_Min
0.01
PSCLK_FREQ_LF_Max
360.00
Output Clocks (High Frequency Mode)
CLK0, CLK180
CLKOUT_FREQ_1X_HF_Min
48.00
CLKOUT_FREQ_1X_HF_Max
360.00
CLKDV
CLKOUT_FREQ_DV_HF_Min
3.00
CLKOUT_FREQ_DV_HF_Max
240.00
CLKFX, CLKFX180
CLKOUT_FREQ_FX_HF_Min
210.00
CLKOUT_FREQ_FX_HF_Max
270.00
Input Clocks (High Frequency Mode)
CLKIN (using DLL outputs) (1), (3)
CLKIN_FREQ_DLL_HF_Min
48.00
CLKIN (using CLKFX outputs) (2), (3)
CLKIN_FREQ_DLL_HF_Max
CLKIN_FRQ_FX_HF_Min
360.00
50.00
CLKIN_FRQ_FX_HF_Max
270.00
PSCLK
PSCLK_FREQ_HF_Min
0.01
PSCLK_FREQ_HF_Max
360.00
Notes:
1. “DLL outputs” is used here to describe the outputs: CLK0, CLK90, CLK180, CLK270, CLK2X, CLK2X180, and CLKDV.
2. If both DLL and CLKFX outputs are used, follow the more restrictive specification.
3. If the CLKIN_DIVIDE_BY_2 attribute of the DCM is used, then double these values.
Units
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
DS122 (v1.1) January 7, 2004
www.xilinx.com
69
Product Specification
1-800-255-7778