13.4.4.23
Small Form Factor Three Port 10/100 Managed Ethernet Switch with Single MII/RMII/Turbo MII
Datasheet
Buffer Manager Port 0 Ingress Rate Drop Count Register (BM_RATE_DRP_CNT_SRC_0)
Register #:
1C16h
Size:
32 bits
This register counts the number of packets received on Port 0 that were dropped by the Buffer
Manager due to ingress rate limit discarding (Red and random Yellow dropping).
BITS
DESCRIPTION
31:0 Dropped Count
These bits count the number of dropped packets received on Port 0 and is
cleared when read.
Note: This counter will stop at its maximum value of FFFF_FFFFh.
Minimum rollover time at 100Mbps is approximately 481 hours.
TYPE
RC
DEFAULT
00000000h
Revision 1.3 (08-27-09)
340
DATASHEET
SMSC LAN9303/LAN9303i