UART2 Special Mode Register
The UART2 special mode register (address 037716) is used to control UART2 in various ways.
Bit 0 of the UART2 special mode register are used as the I2C mode select bit.
Setting “1” in the I2C mode select bit (bit 0) goes the circuit to achieve the I2C bus (simplified I2C bus)
interface effective.
Table 1.15.13 shows the relation between the I2C mode select bit and respective control workings.
Since this function uses clock-synchronous serial I/O mode, set this bit to “0” in UART mode.
Table 1.15.13. Features in I2C mode
Function
Normal mode
1 Factor of interrupt number 10 (Note 2, 4)
Bus collision detection
2 Factor of interrupt number 15 (Note 2)
3 Factor of interrupt number 16 (Note 2)
4 UART2 transmission output delay
5 P70 at the time when UART2 is in use
6 P71 at the time when UART2 is in use
7 P72 at the time when UART2 is in use
8 DMA1 factor at the time when 1101 is assigned to
the DMA request factor selection bits
UART2 transmission
UART2 reception
Not delayed
TxD2 (output)
RxD2 (input)
CLK2
UART2 reception
9 Noise filter width
10 Reading P71
11 Initial value of UART2 output
15ns
Reading the terminal when 0 is
assigned to the direction register
H level (when 0 is assigned to
the CLK polarity select bit)
Note 1: Make the settings given below when I2C mode is in use.
Set 0 1 0 in bits 2, 1, 0 of the UART2 transmission/reception mode register.
Disable the RTS/CTS function. Choose the MSB First function.
Note 2: Follow the steps given below to switch from a factor to another.
1. Disable the interrupt of the corresponding number.
2. Switch from a factor to another.
3. Reset the interrupt request flag of the corresponding number.
4. Set an interrupt level of the corresponding number.
Note 3: Set an initial value of SDA transmission output when serial I/O is invalid.
I2C mode (Note 1)
Start condition detection or stop
condition detection
No acknowledgment detection (NACK)
Acknowledgment detection (ACK)
Delayed
SDA (input/output) (Note 3)
SCL (input/output)
P72
Acknowledgment detection (ACK)
200ns
Reading the terminal regardless of the
value of the direction register
The value set in latch P70 when the
port is selected (Note 3)