M16C26 Datasheet, PDF (104/239 Pages) Renesas Technology Corp – 16-BIT CMOS SINGLE-CHIP MICROCOMPUTER M16C FAMILY / M16C/20 SERIES
Udenvdeelropment
Preliminary Specifications Rev. 0.9
Specifications in this manual are tentative
Three-Phase Motor Control Timer Function
and
subject to change.
SINGLE-CHIP 16-BIT
M16C/26 Group
CMOS MICROCOMPUTER
Trigger select register
b7 b6 b5 b4 b3 b2 b1 b0
Symbol
TRGSR
Address
038316
When reset
0016
Bit symbol
Bit name
TA1TGL Timer A1 event/trigger
select bit
TA1TGH
TA2TGL
TA2TGH
Timer A2 event/trigger
select bit
TA3TGL
TA3TGH
Timer A3 event/trigger
select bit
Function
b1 b0
0 0 : Input on TA1IN is selected (Note)
0 1 : TB2 overflow is selected
1 0 : TA0 overflow is selected
1 1 : TA2 overflow is selected
b3 b2
0 0 : Input on TA2IN is selected (Note)
0 1 : TB2 overflow is selected
1 0 : TA1 overflow is selected
1 1 : TA3 overflow is selected
b5 b4
0 0 : Input on TA3IN is selected (Note)
0 1 : TB2 overflow is selected
1 0 : TA2 overflow is selected
1 1 : TA4 overflow is selected
RW
TA4TGL
TA4TGH
Timer A4 event/trigger
select bit
b7 b6
0 0 : Input on TA4IN is selected (Note)
0 1 : TB2 overflow is selected
1 0 : TA3 overflow is selected
1 1 : TA0 overflow is selected
Note: Set the corresponding port direction register to 0 .
Count start flag
b7 b6 b5 b4 b3 b2 b1 b0
Symbol
TABSR
Address
038016
When reset
0016
Bit symbol
TA0S
TA1S
TA2S
TA3S
TA4S
TB0S
TB1S
TB2S
Bit name
Timer A0 count start flag
Timer A1 count start flag
Timer A2 count start flag
Timer A3 count start flag
Timer A4 count start flag
Timer B0 count start flag
Timer B1 count start flag
Timer B2 count start flag
F unction
0 : Stops counting
1 : Starts counting
RW
Figure 1.14.5. Registers related to timers for three-phase motor control (5)
98