RG82845SL5YQ Datasheet, PDF (75/148 Pages) Intel Corporation – Intel® 845 Chipset: 82845 Memory Controller Hub (MCH) for SDR
Register Description
R
3.5.35
ERRSTS—Error Status Register (Device 0)
Address Offset:
Default Value:
Access:
Size:
C8–C9h
0000h
R/WC
16 bits
This register is used to report various error conditions via the hub interface messages to ICH2. An
SERR, SMI, or SCI error message may be generated via the hub interface on a zero to one
transition of any of these flags when enabled in the PCICMD/ERRCMD, SMICMD, or SCICMD
registers, respectively. These bits are set, regardless of whether or not the SERR is enabled and
generated.
Bit
15:10
9
8:7
6
5
4
3
2
1
Description
Reserved.
LOCK to non-DRAM Memory Flag (LCKF).
0 =Software must write a 1 to clear this status bit.
1 =Indicates that a host initiated LOCK cycle targeting non-DRAM memory space occurred.
Reserved.
SERR on Hub Interface Target Abort (TAHLA).
0 =Software must write a 1 to clear this status bit.
1 =MCH detected that a MCH-originated hub interface cycle was terminated with a Target Abort
completion packet or special cycle.
MCH Detects Unimplemented Hub Interface Special Cycle (HIAUSC).
0 =Software must write a 1 to clear this status bit.
1 =MCH detected an Unimplemented Special Cycle on the hub interface.
AGP Access Outside of Graphics Aperture Flag (OOGF).
0 =Software must write a 1 to clear this status bit.
1 =Indicates that an AGP access occurred to an address that is outside of the graphics aperture
range.
Invalid AGP Access Flag (IAAF).
0 =Software must write a 1 to clear this status bit.
1 =Indicates that an AGP access was attempted outside of the graphics aperture and either to
the 640 KB – 1 MB range or above the top of memory.
Invalid Graphics Aperture Translation Table Entry (ITTEF).
0 =Software must write a 1 to clear this status bit.
1 =Indicates that an invalid translation table entry was returned in response to an AGP access
to the graphics aperture.
Multiple-bit DRAM ECC Error Flag (DMERR).
0 =After software completes the error processing, a value of 1 is written to this bit field to set the
value back to 0 and unlock the error logging mechanism.
1 =A memory read data transfer had an uncorrectable multiple-bit error. When this bit is set, the
address and device number that caused the error are logged in the EAP Register. Software
uses bits [1:0] to detect whether the logged error address is for Single or Multiple-bit error.
Intel® 82845 MCH for SDR Datasheet
75