English
Language : 

CN8478 Datasheet, PDF (193/221 Pages) Conexant Systems, Inc – Multichannel Synchronous Communications Controller (MUSYCC)
CN8478/CN8474A/CN8472A/CN8471A
7.0 Electrical and Mechanical Specifications
Multichannel Synchronous Communications Controller (MUSYCC™)
7.2 Timing and Switching Specifications
Table 7-8. PCI I/O Timing Parameters, 33 MHz PCI Clock
Symbol
Parameter
Min
Max
Unit
Tval
PCLK to Signal Valid Delay—Bused Signal(1, 2, 4)
2
11
ns
Tval (ptp)
PCLK to Signal Valid Delay—Point To Point(1, 2)
2
12
ns
Ton
Float to Active Delay(3)
—
13
ns
Toff
Active to Float Delay(3)
—
28
ns
Tds
Input Setup Time to Clock—Bused Signal(2)
7
—
ns
Tsu (ptp)
Input Setup Time to Clock—Point To Point(2)
10, 12
—
ns
Tdh
Input Hold Time from Clock(5)
0
—
ns
NOTE(S):
(1) Minimum and maximum times are evaluated at 80 pF equivalent load. Actual test capacitance may vary, and results should
be correlated to these specifications.
(2) REQ* and GNT* are the only point-to-point signals and have different output valid delay and input setup times than bused
signals. GNT* has a setup of 10; REQ* has a setup of 12.
(3) For purposes of active/float timing measurements, the high-Z or off state is when the total current delivered through the
component pin is less than or equal to the leakage current specification at 80 pF equivalent load.
(4) TVAL = 17 ns max for INTA.
(5) Tdh = 0.5 ns min for GNT, IDSEL, and IRDY.
Table 7-9. PCI I/O Timing Parameters, 66 MHz PCI Clock
Symbol
Parameter
Min
Max
Units
Tval
PCLK to Signal Valid Delay—Bused Signal(1, 2)
2
6
ns
Tval (ptp)
PCLK to Signal Valid Delay—Point To Point(1, 2)
2
6
ns
Ton
Float to Active Delay(3)
2
—
ns
Toff
Active to Float Delay(3)
—
14
ns
Tds
Input Setup Time to Clock—Bused Signal(2)
3
—
ns
Tsu (ptp)
Input Setup Time to Clock—Point To Point(2)
5
—
ns
Tdh
Input Hold Time from Clock
0
—
ns
NOTE(S):
(1) Minimum and maximum times are evaluated at 80 pF equivalent load. Actual test capacitance may vary, and results should
be correlated to these specifications.
(2) REQ* and GNT* are the only point-to-point signals and have different output valid delay and input setup times than bused
signals. GNT* has a setup of 10; REQ* has a setup of 12.
(3) For purposes of active/float timing measurements, the high-Z or off state is when the total current delivered through the
component pin is less than or equal to the leakage current specification at 80 pF equivalent load.
100660E
Conexant