6.0 Basic Operation
6.4 Protocol Support
SS7 Signal Unit Error Rate
(SUERR) Interrupt
In the case of an SS7 SUERR, an error is detected in SS7 mode which caused a
counter for SS7 related errors to equal or exceed the permitted threshold value.
The threshold is stored on a per-channel group basis in the bit field SUET in a
Group Configuration Descriptor.
Reasons:
⢠A Short SS7 message increments the SS7 counter.
⢠An FCS error in the SS7 message increments the SS7 counter.
⢠An Octet alignment error in the SS7 message.
⢠Accumulation of 16 âoctet countâ type errors increments counter.
NOTE: Receiving 256 unerrored SS7 messages decrements the SS7counter.
Effects:
⢠The Interrupt Descriptor in Interrupt Queue with ERROR = SUERR,
DIR = 0 (if MSKSUERR = 0 in Receive Channel Configuration
Descriptor).
⢠The BLP scans for the opening flag of the next HDLC message.
⢠Simultaneously, DMAC checks for Message Descriptor ownership before
transferring received data to shared memory.
Channel Level Recovery Actions:
⢠None required.
6.4.9 Transparent Mode
MUSYCC supports a transparent mode where no distinction is made between
information and non-information bits in the data bit stream. This mode is
assigned on a per channel and direction basis by the bit field PROTOCOL in the
Channel Configuration Descriptor.
In transparent mode, the following characteristics apply:
⢠All data bits are transferred between shared memory and the serial
interface without protocol support such as those listed for the HDLC
mode.
⢠Host must maintain the necessary data transfer rates at all times by
providing Message Descriptors and data buffers for both the transmit and
receive channels.
⢠The host must always set the bit field EOM to 0 in each Transmit Buffer
Descriptor. Setting EOM to 1 causes indeterminate results. Due to
EOM = 0, the other Transmit Buffer Descriptor bit fieldsâIC, PADEN,
PADCNT, and REPEATâare ineffective.
Unlike HDLC mode, MUSYCC does not poll a host-owned Transmit Buffer
Descriptor during transparent mode.
When the internal buffer is empty and no more transmit data is available from
shared memory (i.e., host-owned buffer), MUSYCC does the following:
1. Issues an ONR error.
2. Enters the channel deactivate state, sending idle code on the affected
channel.