English
Language : 

E702289_SH7290 Datasheet, PDF (226/252 Pages) Renesas Technology Corp – SH7290 E10A Emulator
Table 6.6 lists the combinations of conditions that can be set under Break Condition 1, 2, 3.
Table 6.6 Dialog Boxes for Setting Break Conditions
Type
Dialog Box
Bus
Address Data
State
Bus
Bus
ASID
Condition Count
Internal LDTLB
Condition Condition Condition (Bus
Condition I/O
Instruction
(Address) (Data)
(ASID) Status) (Count) Break Break
[Break Condition 1] O
O
O
O
O
X
X
dialog box
[Break Condition 2] O
X
O
O
X
X
X
dialog box
[Break Condition 3] X
X
X
X
X
O
O
dialog box
Note: O: Can be set in the dialog box.
X: Cannot be set in the dialog box.
6.5.3 Trace Functions
The SH7290 E10A emulator supports the trace functions listed in table 6.7.
Table 6.7 Trace Functions
Function
Branch trace
Range memory access trace
Software trace
Internal Trace
Supported (eight branches)
Not supported
Not supported
AUD Trace
Supported
Supported
Supported
Table 6.8 shows the type numbers that the AUD function can be used.
Table 6.8 Type Number and AUD Function
Type Number
HS7290KCM01H, HS7290KCI01H
HS7290KCM02H, HS7290KCI02H
AUD Function
Not supported
Supported
202