5.2.2 AUD_MODE:AUM
Description:
Sets or displays AUD trace acquisition conditions.
Format:
aum [<option1>] [<option2>]
<option1> = mode<mode>
<option2> = full<full>
Table 5.3 AUD_MODE Command Parameter
Parameter
Type
Description
<mode>
Keyword
Selects the trace mode.
N: Internal trace
F: Non realtime trace
R: Realtime trace
<full>
Keyword
Continues or stops emulation when the trace memory
is full.
C: Always overwrites the oldest information to
acquire the latest information.
S: When the trace buffer memory is full, information
acquisition stops.
Note: When <option1> and <option2> are omitted, the current setting conditions are displayed.
Note: The parameters for this command differ according to the product. For the
specifications of each product, refer to the online help.