(5) [Count] Page ([Break Condition] Dialog Box)
Function:
This page sets the conditions for Break Condition 1.
Window:
Figure 4.16 [Count] Page ([Break Condition] Dialog Box)
Table 4.19 [Count] Page Options
Option
[Don’t Care] check box
Input area
Description
Sets no satisfaction count conditions.
Sets the satisfaction count as a break condition. The maximum
count is 4,095. Breaks when the conditions set by the [Break
Condition] dialog box for the specified times are satisfied. The
default is D’1.
Note: Some products are not supported by this function. For the specifications of each
product, refer to the online help.