English
Language : 

E702289_SH7290 Datasheet, PDF (163/252 Pages) Renesas Technology Corp – SH7290 E10A Emulator
The items listed in the following table are displayed in the [System Status] window.
Table 4.24 [System Status] Window Display Items
Page
[Session]
[Platform]
[Memory]
[Events]
Item
Target System
Session Name
Program Name
Connected To
CPU
Run status
Cause of last break
Run time count
Emulator mode
Big Endian/Little
Endian
AUD
Loaded Memory
Areas
Resources
Description
Always displays Connected.
Displays the session file name.
Displays the load module file name.
Displays the name of the connected emulator and the
selected driver name.
Displays the target device name.
Displays the execution status:
RUNNING: Being executed
Break: Stopped
Displays the cause of the emulator stopping at break. In
this example, the cause of the stop is BREAK POINT.
Displays the program execution time. The display format
is h: hours, min: minutes, s: seconds, and ms:
milliseconds. In this example, 0h:0min:0s:16ms is
displayed.
Displays the emulator operating mode (setting
information for [Emulation Mode] of the [Configuration]
dialog box).
Displays the endian state (Big Endian or Little Endian).
In this example, Big Endian is displayed.
Displays whether the AUD function can be used. This
item is displayed by the emulator with the AUD function.
Displays the loaded area of the load module.
Displays the usage states of BREAKPOINT and Break
Condition.
139