Error Conditions
OVRF individually to generate a receiver/error CPU interrupt request. However, leaving MODFEN low
prevents MODF from being set.
In a master SPI with the mode fault enable bit (MODFEN) set, the mode fault flag (MODF) is set if SS
goes to logic 0. A mode fault in a master SPI causes these events to occur:
• If ERRIE = 1, the SPI generates an SPI receiver/error CPU interrupt request.
• The SPE bit is cleared.
• The SPTE bit is set.
• The SPI state counter is cleared.
• The data direction register of the shared I/O port regains control of port drivers.
NOTE
To prevent bus contention with another master SPI after a mode fault error,
clear all SPI bits of the data direction register of the shared I/O port before
enabling the SPI.
When configured as a slave (SPMSTR = 0), the MODF flag is set if SS goes high during a transmission.
When CPHA = 0, a transmission begins when SS goes low and ends once the incoming SPSCK goes
back to its idle level following the shift of the eighth data bit. When CPHA = 1, the transmission begins
when the SPSCK leaves its idle level and SS is already low. The transmission continues until the SPSCK
returns to its idle level following the shift of the last data bit. See 15.5 Transmission Formats.
NOTE
Setting the MODF flag does not clear the SPMSTR bit. Reading SPMSTR
when MODF = 1 will indicate a mode fault error occurred in either master
mode or slave mode.
When CPHA = 0, a MODF occurs if a slave is selected (SS is at logic 0) and
later unselected (SS is at logic 1) even if no SPSCK is sent to that slave.
This happens because SS at logic 0 indicates the start of the transmission
(MISO driven out with the value of MSB) for CPHA = 0. When CPHA = 1, a
slave can be selected and then later unselected with no transmission
occurring. Therefore, MODF does not occur since a transmission was
never begun.
In a slave SPI (MSTR = 0), the MODF bit generates an SPI receiver/error CPU interrupt request if the
ERRIE bit is set. The MODF bit does not clear the SPE bit or reset the SPI in any way. Software can abort
the SPI transmission by clearing the SPE bit of the slave.
NOTE
A logic 1 voltage on the SS pin of a slave SPI puts the MISO pin in a high
impedance state. Also, the slave SPI ignores all incoming SPSCK clocks,
even if it was already in the middle of a transmission.
To clear the MODF flag, read the SPSCR with the MODF bit set and then write to the SPCR register. This
entire clearing procedure must occur with no MODF condition existing or else the flag is not cleared.
MC68HC908MR32 • MC68HC908MR16 Data Sheet, Rev. 6.1