Bit/Field
1
Name
Mode
0
Enable
LM3S610 Data Sheet
Type
R/W
R/W
Reset
0
0
Description
The mode for the counter. If 0, the counter counts down
from the load value to 0 and then wraps back to the load
value (Count-Down mode). If 1, the counter counts up from
0 to the load value, back down to 0, and then repeats
(Count-Up/Down mode).
Master enable for the PWM generation block. If 0, the entire
block is disabled and not clocked. If 1, the block is enabled
and produces PWM signals.
October 8, 2006