LM3S610_06 Datasheet, PDF (145/396 Pages) List of Unclassifed Manufacturers – Microcontroller | |||
|
◁ |
LM3S610 Data Sheet
9 General-Purpose Timers
Programmable timers can be used to count or time external events that drive the Timer input pins.
The LM3S610 controller General-Purpose Timer Module (GPTM) contains three GPTM blocks
(Timer0, Timer1, and Timer 2). Each GPTM block provides two 16-bit timer/counters (referred to
as TimerA and TimerB) that can be configured to operate independently as timers or event
counters, or configured to operate as one 32-bit timer or one 32-bit Real-Time Clock (RTC).
Timers can also be used to trigger analog-to-digital (ADC) conversions. The trigger signals from all
of the general-purpose timers are ORed together before reaching the ADC module, so only one
timer should be used to trigger ADC events.
The following modes are supported:
 32-bit Timer modes:
â Programmable one-shot timer
â Programmable periodic timer
â Real-Time Clock using 32.768-KHz input clock
â Software-controlled event stalling (excluding RTC mode)
 16-bit Timer modes:
â General-purpose timer function with an 8-bit prescaler
â Programmable one-shot timer
â Programmable periodic timer
â Software-controlled event stalling
 16-bit Input Capture modes:
â Input edge count capture
â Input edge time capture
 16-bit PWM mode:
â Simple PWM mode with software-programmable output inversion of the PWM signal
October 8, 2006
145
Preliminary
|
▷ |