TLK10081
SLLSEE9 – NOVEMBER 2013
Table 6-58. TI_RESERVED_CONTROL
Register Address:0x8021 SPACER Default: 0x000A
Bit(s) Name
Description
15:7
RESERVED
For TI use only (Default 9'b000000000)
6
HS_PLL_LOCK_CHECK_
1 = Disable auto HS pll lock status check.
DISABLE
0 = Enable auto HS pll lock status check (Default 1’b0)
5
HS_LOS_CHECK_DISABLE 1 = Disable auto HS los status check
0 = Enable auto HS los sync status check (Default 1’b0)
4
RESERVED
For TI use only (Default 1’b0)
3
CLKOUT_EN_AUTO_DISABLE This bit controls the signal which flat lines CLKOUT and applicable only when
CLKOUT is selected to have HS Recovered byte clock
1 = CLKOUT clock flat lined if HS LOS is detected (Default 1’b1)
0 = CLKOUT clock not flat lined if HS LOS is detected
2:0
RESERVED
For TI use only (Default 3’b010)
Table 6-59. VS_LS_TX_ERROR_CODE
Register Address:0x8026 SPACER Default: 0x02FE
Bit(s) Name
Description
9:0
LS_TX_ERROR_CODE[9:0] Error code to be transmitted if LS TX FIFO has error (Default 10’h2FE)
Table 6-60. VS_LS_RX_ERROR_CODE
Register Address:0x8027 SPACER Default: 0x02FE
Bit(s) Name
Description
9:0
LS_RX_ERROR_CODE[9:0] Error code to be transmitted if LS RX FIFO has error (Default 10’h2FE)
Table 6-61. VS_HS_RX_ERROR_CODE
Register Address:0x8028 SPACER Default: 0x02FE
Bit(s) Name
Description
9:0
HS_RX_ERROR_CODE[9:0] Error code to be transmitted if HS RX FIFO has error (Default 10’h2FE)
Table 6-62. VS_HS_TX_ERROR_CODE
Register Address:0x8029 SPACER Default: 0x02FE
Bit(s) Name
Description
9:0
HS_TX_ERROR_CODE[9:0] Error code to be transmitted if HS TX FIFO has error (Default 10’h2FE)
Table 6-63. TI_RESERVED_STATUS
Register Address:0x9020 SPACER Default: 0x0000
Bit(s) Name
Description
15:1
RESERVED
For TI use only.
0
LT_START_PROTOCOL
1 = Start up protocol in progress
0 = Start up protocol complete
Table 6-64. LT_LINK_PARTNER_CONTROL
Register Address:0x9098 SPACER Default: 0x0000
Bit(s)
Name
Description
13
LT_LP_PRESET
1 = KR preset coefficients
0 = Normal operation
12
LT_LP_INITIALIZE
1 = Initialize KR coefficients
0 = Normal operation
www.ti.com
Access
RW
RW
RW
RW
RW
RW
Access
RW
Access
RW
Access
RW
Access
RW
Access
RO
RO
Access
RO
RO
46
PROGRAMMERS REFERENCE
Submit Documentation Feedback
Product Folder Links: TLK10081
Copyright © 2013, Texas Instruments Incorporated