English
Language : 

HD64F3664FPV Datasheet, PDF (255/446 Pages) Renesas Technology Corp – Old Company Name in Catalogs and Other Documents
Section 14 Serial Communication Interface 3 (SCI3)
Transmitting
station
Serial transmission line
Receiving
station A
(ID = 01)
Serial
data
Receiving
station B
(ID = 02)
H'01
(MPB = 1)
Receiving
station C
(ID = 03)
H'AA
(MPB = 0)
Receiving
station D
(ID = 04)
ID transmission cycle =
receiving station
specification
Data transmission cycle =
Data transmission to
receiving station specified by ID
[Legend]
MPB: Multiprocessor bit
Figure 14.15 Example of Communication Using Multiprocessor Format
(Transmission of Data H'AA to Receiving Station A)
Rev. 6.00 Mar. 24, 2006 Page 225 of 412
REJ09B0142-0600