Section 12 Timer W
12.5.3 Input Capture Timing
Input capture on the rising edge, falling edge, or both edges can be selected through settings in
TIOR0 and TIOR1. Figure 12.17 shows the timing when the falling edge is selected. The pulse
width of the input capture signal must be at least two system clock (φ) cycles; shorter pulses will
not be detected correctly.
φ
Input capture
input
Input capture
signal
TCNT
N–1
N
N+1
N+2
GRA to GRD
N
Figure 12.17 Input Capture Input Signal Timing
12.5.4 Timing of Counter Clearing by Compare Match
Figure 12.18 shows the timing when the counter is cleared by compare match A. When the GRA
value is N, the counter counts from 0 to N, and its cycle is N + 1.
φ
Compare
match signal
TCNT
N
H'0000
GRA
N
Figure 12.18 Timing of Counter Clearing by Compare Match