English
Language : 

HD64F3664FPV Datasheet, PDF (247/446 Pages) Renesas Technology Corp – Old Company Name in Catalogs and Other Documents
Section 14 Serial Communication Interface 3 (SCI3)
[4]
Error processing
No
OER = 1
Yes
Overrun error processing
No
FER = 1
Yes
Yes
Break?
No
Framing error processing
No
PER = 1
Yes
Parity error processing
(A)
Clear OER, PER, and
FER flags in SSR to 0
<End>
Figure 14.8 Sample Serial Reception Data Flowchart (2)
Rev. 6.00 Mar. 24, 2006 Page 217 of 412