English
Language : 

XRT7250 Datasheet, PDF (41/463 Pages) Exar Corporation – DS3/E3 FRAMER IC
XRT7250 DS3/E3 FRAMER IC
áç
REV. 1.1.1
AC ELECTRICAL CHARACTERISTICS (CONT.)
Test Conditions: TA = 25(C, VCC = 5.0V + 5% unless otherwise specified
SYMBOL
PARAMETER
MIN. TYP. MAX. UNITS
t40 "RxPOS" or "RxNEG" set-up time to falling edge of
3
ns
"RxLineClk".
(Framer is configured to sample data on "RxPOS"
and "RxNEG" input pins, on the falling edge of "RxLi-
neClk")
t41 "RxPOS" or "RxNEG" hold time, from falling edge of 5
ns
"RxLineClk"
(Framer is configured to sample data on "RxPOS"
and "RxNEG" input pins, on the falling edge of "RxLi-
neClk")
Receive Payload Data Output Inteface Timing - Serial Mode Operation (See Figure 11)
t50 Rising edge of RxClk to "Payload Data" (RxSer) out- 10
11
12
ns
put delay
13
14
15
t51 Rising edge of "RxClk" to "RxFrame" output delay
10
11
12
ns
CONDITIONS
DS3 Applications
E3 Applications
DS3 Applications
13
14
15
E3 Applications
t52 Rising edge of "RxClk" to "RxOHInd" output delay.
10
11
12
ns DS3 Applications
13
14
15
E3 Applications
Receive Payload Data Output Interface Timing - Nibble Mode Operation (see Figure 12)
t53 Falling edge of “RxClk” to rising edge of “RxFrame”
output delay
2
ns
t54 Falling edge of “RxClk” to rising edge of “RxNib[3:0]”
output delay
1
ns
Receive Overhead Data Output Interface Timing - Method 1 - Using RxOHEnable (see Figure 13)
t59A Falling edge of “RxOHClk” to “RxFrame” output
20
25
ns DS3 Applications
25
t59B Falling edge of “RxClk” to “RxOH” output delay
20
28
E3 Applications
25
ns DS3 Applications
25
28
E3 Applications
Receive Overheadf Data Output Interface Timing - Method 2 - Using RxOHEnable (see Figure 14)
t60 Rising edge of "RxOutClk" to rising edge of
2
"RxOHEnable" delay.
7
ns
t60A Rising edge of "RxOHFrame" to rising edge of
910
"RxOHEnable" delay
220
930
ns DS3 Applications
240
ns E3, ITU-T G.832
Applications
25
32
ns E3, ITU-T G.751
Applications
22