English
Language : 

XRT7250 Datasheet, PDF (229/463 Pages) Exar Corporation – DS3/E3 FRAMER IC
XRT7250 DS3/E3 FRAMER IC
REV. 1.1.1
áç
FIGURE 89. ILLUSTRATION OF THE SIGNALS THAT ARE OUTPUT VIA THE RECEIVE OVERHEAD OUTPUT INTERFACE
(FOR METHOD 1).
RxOHClk
RxOHFrame
RxOH
X
F1
AIC
F0
FEAC
Terminal Equipment should sample
the “RxOHFrame” and “RxOH” signals
here.
Recommended Sampling Edges
Method 2 - Using RxOutClk and the RxOHEnable
signals
Method 1 requires that the Terminal Equipment be
able to handle an additional clock signal, RxOHClk.
However, there may be a situation in which the Termi-
nal Equipment circuitry does not have the means to
accommodate and process this extra clock signal, in
order to use the Receive Overhead Data Output Inter-
face. Hence, Method 2 is available. Method 2 in-
volves the use of the following signals.
• RxOH
• RxOutClk
• RxOHEnable
• RxOHFrame
Each of these signals are listed and described below
in Table 43.
210