Interrupt System
C517A
Special Function Register IRCON0 (Address C0H)
Reset Value : 00H
Bit No.
C0H
MSB
C7H
EXF2
C6H C5H
TF2 IEX6
C4H C3H C2H
IEX5 IEX4 IEX3
LSB
C1H C0H
IEX2 IADC
IRCON0
Bit
EXF2
TF2
IEX6
IEX5
IEX4
IEX3
IEX2
IADC
Function
Timer 2 external reload flag
Set when a reload is caused by a negative transition on pin T2EX while EXEN2 =
1. If ET2 in IEN0 is set (timer 2 interrupt enabled), EXF2 = 1 will cause an interrupt.
Can be used as an additional external interrupt when the reload function is not
used. EXF2 must be cleared by software.
Timer 2 overflow flag
Set by a timer 2 overflow and must be cleared by software. If the timer 2 interrupt
is enabled, TF2 = 1 will cause an interrupt.
External interrupt 6 edge flag
Set by hardware when external interrupt edge was detected or when a compare
event occurred at pin 1.3/INT6/CC3. Cleared by hardware when processor vectors
to interrupt routine.
External interrupt 5 edge flag
Set by hardware when external interrupt edge was detected or when a compare
event occurred at pin 1.2/INT5/CC2. Cleared by hardware when processor vectors
to interrupt routine.
External interrupt 4 edge flag
Set by hardware when external interrupt edge was detected or when a compare
event occurred at pin 1.1/INT4/CC1. Cleared by hardware when processor vectors
to interrupt routine.
External interrupt 3 edge flag
Set by hardware when external interrupt edge was detected or when a compare
event occurred at pin 1.0/INT3/CC0. Cleared by hardware when processor vectors
to interrupt routine.
External interrupt 2 edge flag
Set by hardware when external interrupt edge was detected or when a compare
event occurred at pin 1.4/INT2/CC4. Cleared by hardware when processor vectors
to interrupt routine.
A/D converter interrupt request flag
Set by hardware at the end of a conversion. Must be cleared by software.