English
Language : 

MC68HC05B4 Datasheet, PDF (273/298 Pages) Motorola, Inc – High-density Complementary Metal Oxide Semiconductor (HCMOS) Microcomputer Unit
H.9
Control timing
Preliminary Table H-11 Control timing for 5V operation
(VDD = 5.0 Vdc ± 10%, VSS = 0 Vdc, TA = –40 to +85°C)
Characteristic
Symbol
Min
Max
Frequency of operation
Crystal option
External clock option
fOSC
—
4.2
fOSC
dc
4.2
Internal operating frequency (fOSC /2)
Using crystal
Using external clock
fOP
—
2.1
fOP
dc
2.1
Cycle time (see Figure 9-1)
tCYC
476
—
Crystal oscillator start-up time (see Figure 9-1) Ot XOV
—
100
Unit
MHz
MHz
MHz
MHz
ns
ms
Stop recovery start-up time (crystal oscillator)
ILt CH
100
ms
RC oscillator stabilization time
At DRC
5
µs
A/D converter stabilization time
tADON
500
µs
Preliminary External RESET input pulse width
Power-on RESET output pulse width
4064 cycle
16 cycle
Watchdog RESET output pulse width
Watchdog time-out
EEPROM byte erase time
0 to 70 (standard)
– 40 to 85 (extended)
EEPROM byte program time (1)
0 to 70 (standard)
– 40 to 85 (extended)
Timer (see Figure H-10)
Resolution(2)
tRL
tPORL
tPORL
t DOGL
t DOG
tERA
tER A
tPR OG
tPR O G
tRESL
3.0
—
4064
—
16
—
1.5
—
6144
7168
10
—
10
—
10
—
10
—
4
—
t CYC
tCYC
tCYC
t CYC
t CYC
ms
ms
ms
ms
tCYC
Input capture pulse width
Input capture pulse period
tTH, tTL
125
tTLTL
— (3)
—
ns
—
tCYC
Interrupt pulse width (edge-triggered)
ItLIH
125
—
ns
Preliminary Interrupt pulse period
OSC1 pulse width (5)
Write/Erase endurance(6)(7)
Data retention(6)(7)
tILIL
tOH , tOL
—
—
— (4)
—
90
—
10000
10
t CYC
ns
cycles
years
(1) For bus frequencies less than 2 MHz, the internal RC oscillator should be used when
programming the EEPROM.
(2) Since a 2-bit prescaler in the timer must count four external cycles C(tYC ), this is the limiting factor
in determining the timer resolution.
(3) The minimum period tTLTL should not be less than the number of cycle times it takes to execute
the capture interrupt service routine plus 24 Ct YC .
(4) The minimum period tILIL should not be less than the number of cycle times it takes to execute
the interrupt service routine plus 21 Ct YC .
(5) tOH and tOL should not total less than 238ns.
(6) At a temperature of 85°C
(7) Refer to Reliability Monitor Report (current quarterly issue) for current failure rate information.
14
MC68HC05B6
Rev. 4
MC68HC705B32
TPG
MOTOROLA
H-27