English
Language : 

EP2C8T144I8N Datasheet, PDF (146/470 Pages) Altera Corporation – Cyclone II Device Handbook, Volume 1
Timing Specifications
Table 5–42. Cyclone II I/O Output Delay for Column Pins (Part 6 of 6)
I/O Standard
Drive
Strength
Parameter
Fast Corner
Industrial/ Commer
Automotive -cial
–6
Speed
Grade
–7
Speed
Grade
(2)
–7
Speed
Grade
(3)
–8
Speed
Grade
Unit
1.5V_DIFFERENTIAL 16 mA tO P
_HSTL_CLASS_II (1)
tD I P
LVDS
—
tO P
tD I P
RSDS
—
tO P
tD I P
MINI_LVDS
—
tO P
tD I P
SIMPLE_RSDS
—
tO P
tD I P
1.2V_HSTL
—
tO P
tD I P
1.2V_DIFFERENTIAL — tO P
_HSTL
tD I P
1750
1882
1258
1390
1258
1390
1258
1390
1221
1353
2403
2535
2403
2535
1836
1975
1319
1458
1319
1458
1319
1458
1280
1419
2522
2661
2522
2661
3844 4125 4399 4406 ps
4014 4319 4625 4625 ps
2243 2344 2438 2445 ps
2413 2538 2664 2664 ps
2243 2344 2438 2445 ps
2413 2538 2664 2664 ps
2243 2344 2438 2445 ps
2413 2538 2664 2664 ps
2258 2435 2605 2612 ps
2428 2629 2831 2831 ps
4635 5344 6046 6053 ps
4805 5538 6272 6272 ps
4635 5344 6046 6053 ps
4805 5538 6272 6272 ps
Notes to Table 5–42:
(1) This is the default setting in the Quartus II software.
(2) These numbers are for commercial devices.
(3) These numbers are for automotive devices.
5–42
Cyclone II Device Handbook, Volume 1
Altera Corporation
February 2008