EP2C8T144I8N Datasheet, PDF (105/470 Pages) Altera Corporation – Cyclone II Device Handbook, Volume 1 | |||
|
◁ |
5. DC Characteristics and
Timing Specifications
CII51005-4.0
Operating
Conditions
Cyclone® II devices are offered in commercial, industrial, automotive,
and extended temperature grades. Commercial devices are offered in â6
(fastest), â7, and â8 speed grades.
All parameter limits are representative of worst-case supply voltage and
junction temperature conditions. Unless otherwise noted, the parameter
values in this chapter apply to all Cyclone II devices. AC and DC
characteristics are specified using the same numbers for commercial,
industrial, and automotive grades. All parameters representing voltages
are measured with respect to ground.
Tables 5â1 through 5â4 provide information on absolute maximum
ratings.
Table 5â1. Cyclone II Device Absolute Maximum Ratings Notes (1), (2)
Symbol
Parameter
Conditions
Minimum Maximum Unit
VCCINT
Supply voltage
With respect to ground
â0.5
1.8
V
VCCIO
Output supply voltage
â0.5
4.6
V
VCCA_PLL [1..4] PLL supply voltage
â0.5
1.8
V
VIN
DC input voltage (3)
â
â0.5
4.6
V
IOUT
DC output current, per pin
â
â25
40
mA
TSTG
Storage temperature
No bias
â65
150
°C
TJ
Junction temperature
BGA packages under bias
â
125
°C
Notes to Table 5â1:
(1) Conditions beyond those listed in this table cause permanent damage to a device. These are stress ratings only.
Functional operation at these levels or any other conditions beyond those specified in this chapter is not implied.
Additionally, device operation at the absolute maximum ratings for extended periods of time may have adverse
effect on the device reliability.
(2) Refer to the Operating Requirements for Altera Devices Data Sheet for more information.
(3) During transitions, the inputs may overshoot to the voltage shown in Table 5â4 based upon the input duty cycle.
The DC case is equivalent to 100% duty cycle. During transition, the inputs may undershoot to â2.0 V for input
currents less than 100 mA and periods shorter than 20 ns.
Altera Corporation
5â1