5. Debugging Functions
5.13.8 Setting Ranges for Task Profile Measurement
Choose Set Range from the popup menu that is displayed when you right-click in the window.
The Realtime Profile Setting dialog box will be displayed. Set a profile measurement range in this dialog box.
[Task profile mode]
Figure 5.104 Realtime Profile Setting dialog box
(1) Automatic detection of tasks
If you have downloaded a load module that includes an OS, the E100 emulator automatically detects the tasks.
(2) Selecting tasks
Select the checkboxes next to the IDs of tasks you want to measure (by default, all checkboxes are selected).
The selected tasks will automatically be assigned block numbers (1–8).
CAUTION
When the eight blocks have been used up, the block number column for further tasks will be blank, indicating that
measurement for tasks with these IDs is not possible. In such cases, deselect checkboxes against the IDs of tasks for which
performance measurement is not necessary.