5. Debugging Functions
5.7.4 Registering Events
“Registering an event” refers to placing an event in the list of registered events. A registered event can be reused at a later time.
Select one of the following ways to register an event. Up to 256 events can be registered.
(1) Registering events
[Creating an event in the Event dialog box]
1. Open the Comment page of the Event dialog box and select the “Add this event to the list” checkbox. Then click on the
OK button.
Figure 5.36 Event dialog box
2. The event is added at the specified position and registered in the Registered Events dialog box at the same time.
Figure 5.37 Hardware Break dialog box and Registered Events dialog box
REJ10J1831-0200 Rev.2.00 Jun.1, 2009
Page 114 of 228