5. Debugging Functions
Lines for addresses beyond the area to which coverage memory has been allocated are grayed-out. Although any existing
coverage information for such addresses is retained, the coverage information will not be updated by program execution.
Acquired coverage information is accumulated in memory until it is cleared by the user.
5.12.7 Clearing Data Coverage Information
(1) Clearing the data coverage information for a specified range
Selecting Clear Coverage Range from the popup menu on the Address Range or Section sheet opens the Clear Coverage Range
dialog box.
Figure 5.95 Clear Coverage Range dialog box
Enter the addresses where the range to be cleared starts and ends. Clicking on the OK button then clears the coverage
information for the selected range.
(2) Clearing all of the data coverage information
Selecting Clear the Entire Coverage from the popup menu clears all of the data coverage information.
5.12.8 Updating Coverage Information
Selecting Refresh from the popup menu updates the content of the Data Coverage window.
If Lock Refresh has been selected, the information is not automatically updated when program execution breaks. To view the
latest information, therefore, you must manually select updating.
5.12.9 Preventing Updates to Coverage Information
Selecting Lock Refresh from the popup menu prevents updates to the Data Coverage window while the execution of the user
program is stopped.