5. Debugging Functions
5. Repeat fill until full
For each time trace point encountered, information for a total of 512 cycles before and after that point is acquired.
Acquisition continues in the same way until the trace memory overflows, at which time acquisition is halted. The positions
where trace points have been encountered can be checked in the Trace window.
Table 5.19 Specifiable conditions: Repeat fill until full
Trace point
Delay
Specifying capture/do not
capture
Possible
-
-
Recording of step
execution
-
CAUTION
If trace points are encountered in consecutive cycles in the repeat fill until stop or repeat fill until full mode, the yellow
highlight that indicates a trace point only appears for the trace point in the first of the cycles.
5.9.5 Setting Trace Points
(1) Setting trace points
For trace points, you can set an OR condition, other conditions (AND (cumulative), AND (simultaneous), subroutine,
sequential or state transitions) and detection of exceptional events.
You can specify all or only one of the OR condition, other conditions and detection of exceptional events at a time.
OR condition
->
Other conditions
AND (cumulative)
AND (simultaneous) ->
Subroutine
Sequential
State transitions
Trace acquisition
↓
Trace point encountered
Exceptional event
->
Figure 5.50 A trace point in outline
↓
Trace acquisition halted
} Delay value
REJ10J1831-0200 Rev.2.00 Jun.1, 2009