5. Debugging Functions
The contents displayed in this window are listed below.
Table 5.23 Columns and contents
Column
Description
No
Numbers from 1–8 that are assigned to the measurement sections set up in the Performance
Analysis Conditions dialog box.
Click Settings on the popup menu to open the Performance Analysis Conditions dialog box.
Condition
The entry is “Enable” when a measurement condition is set in the Performance Analysis
Conditions dialog box.
Otherwise, the entry is “Disable”.
Run time
Cumulative execution time. This is the cumulative total of measured execution times.
(h:m:s.ms.us.ns)
Count
Shows the number of times measurement for the section has proceeded.
Statistic
Shows the ratio of the cumulative execution time relative to the Go–Break execution time.
[Ratio calculation formula]
(Cumulative execution time / Go–Break cumulative execution time) * 100
Max (h:m:s.ms.us.ns)
Maximum execution time per measurement performed
Min (h:m:s.ms.us.ns)
Minimum execution time per measurement performed
Average (h:m:s.ms.us.ns) Average execution time per measurement performed
5.10.3 Setting Performance Measurement Conditions
In the Performance Analysis window, select the line of a section number to use for the condition and choose Set from the
popup menu. The Performance Analysis Conditions dialog box will be displayed.
Figure 5.67 Performance Analysis Conditions dialog box
REJ10J1831-0200 Rev.2.00 Jun.1, 2009