5. Debugging Functions
(3) Setting other conditions
You can select one from among five available choices: AND (cumulative), AND (simultaneous), Subroutine, Sequential and
State transitions. To set any condition, select the checkbox to the left of “Other conditions.” Other conditions are disabled by
default (the checkbox to the left of “Other conditions” is not selected). Cumulative AND is listed as “AND(Accumulation)” in
the dialog box.
Figure 5.44 Hardware Break dialog box
Table 5.12 Other conditions
Type
Description
AND (cumulative)
A breakpoint is encountered when all of the specified events have occurred regardless of
their timing and order.
AND (simultaneous) A breakpoint is encountered when all of the specified events occur at the same time.
Subroutine
A breakpoint is encountered when a specified event occurs within a specified address range
(subroutine or function).
Sequential
6 steps (forward direction) + reset point
A breakpoint is encountered when the specified events occur in a specified order.
State transitions
3 steps, 9 paths + reset point
A breakpoint is encountered when the specified events occur in a specified order.
The events shown in the list for each condition can be deleted by the keys Ctrl + Del.