5. Debugging Functions
(2) Task profile
Performance of individual tasks can be measured.
For a task, the Realtime Profile window shows its ID, the number of passes, cumulative execution time, the ratio of this to the
overall execution time, and the average execution time.
5.13.2 Selecting a Realtime Profile Measurement Mode
Choose Set Range from the popup menu that is displayed when you right-click in the window.
The Realtime Profile Setting dialog box will be displayed. In the Realtime Profile Mode list box of this dialog box, you can
select âFunction Profileâ or âTask Profile.â
When the profile mode is changed, all results of measurement are cleared.
REJ10J1831-0200 Rev.2.00 Jun.1, 2009
Page 177 of 228
|
▷ |