English
Language : 

R0E417250MCU00 Datasheet, PDF (143/228 Pages) Renesas Technology Corp – E100 Emulator MCU Unit for H8SX/1700 Series
R0E417250MCU00 User’s Manual
5. Debugging Functions
(1) Search history
The search conditions that have been used are recorded in the History column and are retained throughout a session of the
High-performance Embedded Workshop.
If you want to perform a search again, choose the corresponding line from the history and click on the Add button to initiate a
new search for trace information with the same condition.
Up to the last 10 searches are retained in the search history.
(2) OR search
You can perform a search with two or more search conditions combined in an OR condition.
To set an OR condition, begin by setting the first condition (shown on the first line in the Find Setting Contents column) and
then click on the New button.
Then enter the second condition. At this time, the second condition is added as a second line in the Find Setting Contents
column.
In this case, the search is for lines satisfying the logical OR of the conditions on the first and second lines in the Find Setting
Contents column.
Up to 16 conditions (16 lines) can be set.
CAUTION
Conditions set on the same line of the Find Setting Contents column are treated as an AND condition.
5.9.11 Saving Trace Information in Files
To save trace information in a file, choose File -> Save from the popup menu or click on the Save toolbar button [
trace information displayed in the Trace window is saved in a binary or text format.
]. The
(1) Saving in the binary format
To save trace information in the binary format, choose “Trace Data File: Memory Image (*.rtt)” in the Save As Type list box
of the dialog box that is displayed when you choose File -> Save from the popup menu.
When information is saved in the binary format, information for all cycles is saved. This type of file can be loaded back into
the Trace window.
(2) Saving in the text format
To save trace information in the text format, choose “Text Files: Save Only (*.txt)” in the Save As Type list box of the dialog
box that is displayed when you choose File -> Save from the popup menu.
When information is saved in the text format, saving of information for a range of cycles can be specified. This type of file can
only be saved and cannot be loaded back into the Trace window.
REJ10J1831-0200 Rev.2.00 Jun.1, 2009
Page 143 of 228