Section 18 Electrical Characteristics
Item
Applicable
Values
Reference
Symbol Pins
Test Condition Min Typ Max Unit Figure
RES pin low
width
tREL
RES
At power-on and in trc
modes other than
those below
â
â
ms Figure 18.2
In active mode and 200 â
â
ns
sleep mode
operation
Input pin high
tIH
width
NMI,
IRQ0, IRQ3,
WKP0 to
WKP5,
TMCIV,
TMRIV,
TRGV,
ADTRG,
FTCI,
FTIOA to
FTIOD
2
â
â
tcyc Figure 18.3
Input pin low
tIL
width
NMI,
IRQ0, IRQ3,
WKP0 to
WKP5,
TMCIV,
TMRIV,
TRGV,
ADTRG,
FTCI,
FTIOA to
FTIOD
2
â
â
tcyc
Notes: 1. When an external clock is input, the minimum system clock oscillator frequency is
1.0 MHz.
2. Determined by MA2 to MA0 in system control register 2 (SYSCR2).
Rev. 4.00 Sep. 23, 2005 Page 260 of 354