English
Language : 

Z80181 Datasheet, PDF (48/74 Pages) Zilog, Inc. – SMART ACCESS CONTROLLER (SAC™)
Zilog
ABSOLUTE MAXIMUM RATINGS
Z80181
SMART ACCESS CONTROLLER SAC™
Voltage on V with respect to V ........... –0.3V to +7.0V
CC
SS
Voltages on all inputs
with respect to V ........................... –0.3V to V +0.3V
SS
CC
Storage Temperature ............................ –65°C to +150°C
Operating Ambient
Temperature ........................ See Ordering Information
Stresses greater than those listed under Absolute Maxi-
mum Ratings may cause permanent damage to the de-
vice. This is a stress rating only; operation of the device at
any condition above those indicated in the operational
sections of these specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods
may affect device reliability.
STANDARD TEST CONDITIONS
The DC Characteristics and capacitance sections below
apply for the following standard test conditions, unless
otherwise noted. All voltages are referenced to GND (0V).
Positive current flows into the referenced pin (Figure 59).
Available operating
temperature range is: E = –40°C to +100°C
Voltage Supply Range: +4.50V ≤ Vcc ≤ + 5.50V
All AC parameters assume a load capacitance of 100 pF.
Add 10 ns delay for each 50 pF increase in load up to a
maximum of 150 pF for the data bus and 100 pF for
address and control lines. AC timing measurements are
referenced to 1.5 volts (except for clock, which is refer-
enced to the 10% and 90% points). Maximum capacitive
load for CLK is 125 pF.
From Output
Under Test
100 pf
+5V
2.1 K
250 µA
Figure 59. Standard Test Circuit
2-48
DS971800500