English
Language : 

DS92LV2411_15 Datasheet, PDF (14/54 Pages) Texas Instruments – 5 to 50 MHz 24-Bit Channel Link II Serializer And Deserializer
DS92LV2411, DS92LV2412
SNLS302E – MAY 2010 – REVISED FEBRUARY 2015
7.8 Recommended Timing For The Serial Control Bus
Over recommended operating supply and temperature ranges unless otherwise specified.
PARAMETER
TEST CONDITIONS
fSCL
SCL Clock Frequency
Standard Mode
Fast Mode
tLOW
SCL Low Period
Standard Mode
Fast Mode
tHIGH
SCL High Period
Standard Mode
Fast Mode
tHD;STA
Hold time for a start or a
repeated start condition,
Figure 18
Standard Mode
Fast Mode
tSU:STA
Set Up time for a start or a
repeated start condition,
Figure 18
Standard Mode
Fast Mode
tHD;DAT
Data Hold Time,
Figure 18
Standard Mode
Fast Mode
tSU;DAT
Data Set Up Time,
Figure 18
Standard Mode
Fast Mode
tSU;STO
Set Up Time for STOP
Condition, Figure 18
Standard Mode
Fast Mode
tBUF
Bus Free Time
Standard Mode
Between STOP and START,
Figure 18
Fast Mode
tr
SCL and SDA Rise Time,
Standard Mode
Figure 18
Fast Mode
tf
SCL and SDA Fall Time,
Standard Mode
Figure 18
Fast mode
www.ti.com
MIN TYP MAX UNIT
100 kHz
400 kHz
4.7
µs
1.3
µs
4.0
µs
0.6
µs
4.0
µs
0.6
µs
4.7
µs
0.6
µs
0
3.45 µs
0
0.9 µs
250
ns
100
ns
4.0
µs
0.6
µs
4.7
µs
1.3
µs
1000 ns
300 ns
300 ns
300 ns
A
CA
A' Scope
50:
50:
B
CB
B'
50:
50:
Figure 1. Serializer Test Circuit
DOUT+
DOUT-
GND
VOD+
VOS
VOD-
(DOUT+) - (DOUT+)
VOD+
VODp-p
0V
VOD-
Figure 2. Serializer Output Waveforms
14
Submit Documentation Feedback
Copyright © 2010–2015, Texas Instruments Incorporated
Product Folder Links: DS92LV2411 DS92LV2412