Kintex UltraScale FPGAs Data Sheet: DC and AC Switching Characteristics
Table 3: DC Characteristics Over Recommended Operating Conditions
Symbol
Description
Min
Typ(1)
Max Units
VDRINT
Data retention VCCINT voltage (below which configuration
data might be lost)
0.82
â
â
V
VDRAUX
Data retention VCCAUX voltage (below which configuration
data might be lost)
1.50
â
â
V
IREF
IL
CIN(3)
VREF leakage current per pin
â
â
15
µA
Input or output leakage current per pin (sample-tested)
â
â
15(2)
µA
Die input capacitance at the pad (HP I/O)
â
â
3.75
pF
Die input capacitance at the pad (HR I/O)
â
â
7.00
pF
IRPU
IRPD
ICCADC
Pad pull-up (when selected) at VIN = 0V, VCCO = 3.3V
75
Pad pull-up (when selected) at VIN = 0V, VCCO = 2.5V
50
Pad pull-up (when selected) at VIN = 0V, VCCO = 1.8V
60
Pad pull-up (when selected) at VIN = 0V, VCCO = 1.5V
30
Pad pull-up (when selected) at VIN = 0V, VCCO = 1.2V
10
Pad pull-down (when selected) at VIN = 3.3V
60
Pad pull-down (when selected) at VIN = 1.8V
29
Analog supply current per SYSMON instance in powered up
state.
â
â
175
µA
â
169
µA
â
678
µA
â
450
µA
â
262
µA
â
190
µA
â
685
µA
â
19.2
mA
IBATT(4)
Battery supply current
â
â
150
nA
Calibrated programmable on-die termination (DCI) in HP I/O banks(6) (measured per JEDEC specification)
Thevenin equivalent resistance of programmable input
termination to VCCO/2 where ODT = RTT_40
â10%(5)
40
+10%(5) Ω
Thevenin equivalent resistance of programmable input
termination to VCCO/2 where ODT = RTT_48
â10%(5)
48
+10%(5) Ω
Thevenin equivalent resistance of programmable input
termination to VCCO/2 where ODT = RTT_60
â10%(5)
60
+10%(5) Ω
R(7)
Programmable input termination to VCCO where
ODT = RTT_40
â10%(5)
40
+10%(5) Ω
Programmable input termination to VCCO where
ODT = RTT_48
â10%(5)
48
+10%(5) Ω
Programmable input termination to VCCO where
ODT = RTT_60
â10%(5)
60
+10%(5) Ω
Programmable input termination to VCCO where
ODT = RTT_120
â10%(5)
120 +10%(5) Ω
Programmable input termination to VCCO where
ODT = RTT_240
â10%(5)
240 +10%(5) Ω
DS892 (v1.12) April 1, 2016
Product Specification
www.xilinx.com
Send Feedback
5
|
▷ |