Kintex UltraScale FPGAs Data Sheet: DC and AC Switching Characteristics
Power-On/Off Power Supply Sequencing
The recommended power-on sequence is VCCINT/VCCINT_IO, VCCBRAM, VCCAUX/VCCAUX_IO, and VCCO to
achieve minimum current draw and ensure that the I/Os are 3-stated at power-on. The recommended
power-off sequence is the reverse of the power-on sequence. If VCCINT/VCCINT_IO and VCCBRAM have the
same recommended voltage levels, they can be powered by the same supply and ramped simultaneously.
VCCINT_IO must be connected to VCCINT. If VCCAUX/VCCAUX_IO and VCCO have the same recommended
voltage levels, they can be powered by the same supply and ramped simultaneously. VCCAUX and VCCAUX_IO
must be connected together. When the current minimums are met, the device powers on after the
VCCINT/VCCINT_IO, VCCBRAM, VCCAUX/VCCAUX_IO, and VCCO supplies have all passed through their power-on
reset threshold voltages. The device must not be configured until after VCCINT is applied.
VCCADC and VREF can be powered at any time and have no power-up sequencing recommendations.
The recommended power-on sequence to achieve minimum current draw for the GTH or GTY transceivers
is VCCINT, VMGTAVCC, VMGTAVTT OR VMGTAVCC, VCCINT, VMGTAVTT. There is no recommended sequencing for
VMGTVCCAUX. Both VMGTAVCC and VCCINT can be ramped simultaneously. The recommended power-off
sequence is the reverse of the power-on sequence to achieve minimum current draw. If these
recommended sequences are not met, current drawn from VMGTAVTT can be higher than specifications
during power-up and power-down.
DS892 (v1.12) April 1, 2016