English
Language : 

SH7125 Datasheet, PDF (380/782 Pages) Renesas Technology Corp – Renesas 32-Bit RISC Microcomputer
Section 9 Multi-Function Timer Pulse Unit 2 (MTU2)
Operation when Error Occurs during PWM Mode 1 Operation, and Operation is Restarted
in Phase Counting Mode: Figure 9.133 shows an explanatory diagram of the case where an error
occurs in PWM mode 1 and operation is restarted in phase counting mode after re-setting.
1
2
3
RESET TMDR TOER
(PWM1) (1)
4
5
6
TIOR PFC TSTR
(1 init (MTU2) (1)
0 out)
7
Match
8
9
10
Error PFC TSTR
occurs (PORT) (0)
11
TMDR
(PCM)
12 13 14
TIOR PFC TSTR
(1 init (MTU2) (1)
0 out)
MTU2 module output
TIOC*A
TIOC*B
Not initialized (TIOC*B)
Port output
PEn
High-Z
PEn
High-Z
n = 0 to 15
Figure 9.133 Error Occurrence in PWM Mode 1, Recovery in Phase Counting Mode
1 to 10 are the same as in figure 9.130.
11. Set phase counting mode.
12. Initialize the pins with TIOR.
13. Set MTU2 output with the PFC.
14. Operation is restarted by TSTR.
Note: Phase counting mode can only be set for channels 1 and 2, and therefore TOER setting is
not necessary.
Rev. 3.00 Sep. 27, 2007 Page 360 of 758
REJ09B0243-0300