Section 9 Multi-Function Timer Pulse Unit 2 (MTU2)
Operation when Error Occurs during Normal Mode Operation, and Operation is Restarted
in PWM Mode 1: Figure 9.125 shows an explanatory diagram of the case where an error occurs
in normal mode and operation is restarted in PWM mode 1 after re-setting.
1
2
3
RESET TMDR TOER
(normal) (1)
MTU2 module output
TIOC*A
4
5
6
TIOR PFC TSTR
(1 init (MTU2) (1)
0 out)
7
8
9
10
11
12
13
14
Match Error PFC TSTR TMDR TIOR PFC TSTR
occurs (PORT) (0) (PWM1) (1 init (MTU2) (1)
0 out)
TIOC*B
Not initialized (TIOC*B)
Port output
PEn
High-Z
PEn
High-Z
n = 0 to 15
Figure 9.125 Error Occurrence in Normal Mode, Recovery in PWM Mode 1
1 to 10 are the same as in figure 9.124.
11. Set PWM mode 1.
12. Initialize the pins with TIOR. (In PWM mode 1, the TIOC*B side is not initialized. If
initialization is required, initialize in normal mode, then switch to PWM mode 1.)
13. Set MTU2 output with the PFC.
14. Operation is restarted by TSTR.