15) IAREF_MAX is valid for the minimum specified conversion time. The current flowing during an ADC conversion
with a duration of up to tC = 25µs can be calculated with the formula IAREF_MAX = QCONV/tC. Every conversion
needs a total charge of QCONV = 150pC from VAREF.
All ADC conversions with a duration longer than tC = 25µs consume an IAREF_MAX = 6µA.
16) For the definition of the parameters see also Figure 4-2.
17) Applies to AIN0 and AIN1, when used as auxiliary reference inputs.
18) This represents an equivalent switched capacitance. This capacitance is not switched to the reference voltage
at once. Instead of this smaller capacitances are successively switched to the reference voltage.
19) The sampling capacity of the conversion C-Network is pre-charged to VAREF/2 before the sampling moment.
Because of the parasitic elements the voltage measured at AINx is lower then VAREF/2.
A/D Converter Module
fCLC
Fractional
Divider
fDIV
Programmable
Clock Divider
fBC
(1:1) to (1:256)
Sample
1:4
fANA Programmable Time tS
Counter
Arbiter
(1:20)
fTIMER
CON.CTC
Control Unit
(Timer)
CHCONn.STC
Control/Status Logic
Interrupt Logic
External Trigger Logic
External Multiplexer Logic
Request Generation Logic
Figure 4-1 ADC0 Clock Circuit
MCA04657_mod
Data Sheet
99
V1.0, 2008-04